Libratherm .Signal Isolator DC to DC Signal – ISM-10-1-1
₹1,000.00
Parameters | Description |
---|---|
Input | 1) RTD(Pt-100) |
2) Cr/AL – K type thermocouple | |
Range | -50 to 100 °C, 0 to 200 °C and 0 to 400 °C for RTD (Pt-100) |
0 to 400 °C, 0 to 800 °C, 0 to 1200 °C | |
Output | (4-20) mA, (0-5)VDC, (0-10) VDC |
For current output, RL (max) = 500 Ohms. | |
For voltage output, RL (min) = 100K Ohms. | |
No. of Outputs | Maximum 2 parallel independent outputs can be provided for single input. Each output can be same or different. |
Accuracy | Output will be linear to the resistance value of the RTD (Pt-100) and emf/millivolt generated by the thermocouple. |
Calibration | On site calibration facility through ZERO and SPAN presets accessible to the user. |
Isolation | Input and Output are optically isolated for DC inputs and galvanically isolated for the AC inputs. Power supply is also isolated from Input and Output.(3 way isolation) |
Isolation Voltage | Greater than 1 KV. |
Mounting | 35-mm. DIN rail mounting ABS enclosure. |
Supply | AC Supply : 230VAC +/-10%, 50/60Hz or |
DC Supply : 24VDC (18-36)VDC. | |
Size | 45 x 75 x 110 |
- Description
- Additional information
Description
Accepts K type thermocouple or RTD (Pt-100) sensors as the inputs and provides optically isolated and proportional V/I analogue output.
- On site calibration facility-using ZERO/SPAN presets.
- Operates on 230VAC/110VAC or 24VDC (18-36)VDC.
- Designed using ultra low drift components for long term stability.
- Interface of low-level signals coming from the sensors or transducers from the plant to DCS, SCADA, PLC or PID process controllers without ground line interferences
- Signal multiplier – single input and 2 to 4 outputs.
-
Parameters Description Input 1) RTD(Pt-100) 2) Cr/AL – K type thermocouple Range -50 to 100 °C, 0 to 200 °C and 0 to 400 °C for RTD (Pt-100) 0 to 400 °C, 0 to 800 °C, 0 to 1200 °C Output (4-20) mA, (0-5)VDC, (0-10) VDC For current output, RL (max) = 500 Ohms. For voltage output, RL (min) = 100K Ohms. No. of Outputs Maximum 2 parallel independent outputs can be provided for single input. Each output can be same or different. Accuracy Output will be linear to the resistance value of the RTD (Pt-100) and emf/millivolt generated by the thermocouple. Calibration On site calibration facility through ZERO and SPAN presets accessible to the user. Isolation Input and Output are optically isolated for DC inputs and galvanically isolated for the AC inputs (3 way isolation) Isolation Voltage Greater than 1 KV. Mounting 35-mm. DIN rail mounting ABS enclosure. Supply AC Supply : 230VAC +/-10%, 50/60Hz or DC Supply : 24VDC (18-36)VDC. Size 45 x 75 x 110
Additional information
Weight | 1 kg |
---|---|
Dimensions | 200 × 200 × 100 cm |